Intelligent Electroplating Rectifier
Category:
Intelligent rectifier
Continuous Electroplating Industry Applications
Keywords:
Electroplating rectifier
Product Description
Product Features
Microcontroller control
● Real-time monitoring of AC input status, output voltage and current values, ambient temperature, amp-hour calculation and cumulative totals, as well as a three-stage time control function.
● Automatically detects whether the voltage exceeds the limit and issues a warning signal. Measurement values can be displayed at the monitoring center, and reports are automatically generated.
● Multiple waveform options for output, meeting the needs of different plating types and process trials.
● High-speed RS-485/422 communication interface for centralized monitoring of the power supply’s operating status.
● Analog signal input and output interfaces for easy connection to PLCs.
Scope of application
When used in conjunction with a PLC, the entire line achieves computerized management.
PLC control Make
1. PLC to rectifier signal:
a) Digital signals: Control: Start/stop switching; voltage stabilization/current stabilization switching.
b) Analog signals: Current control: 4–20 mA; Voltage control: 0–10 V.
2. Rectifier to PLC signal:
a) Three digital inputs: distiller start/stop status, voltage stabilization/current stabilization status, and fault alarm status.
b) Two analog signals—either 4-20mA current signals or 0-10V voltage signals—to provide feedback on the rectifier’s output voltage and output current.
c) Complete electrical isolation between the rectifier and the PLC.
d) Linear accuracy ≤ 1% (corresponding to the actual output and feedback value of the rectifier for the PLC analog control signal)
e) The rectifier is equipped with a soft-start function, meaning that when the output regulation control signal undergoes a sudden change, the rectifier’s output will gradually transition over a period of time (this function can be selected by the customer).

RS-485 Communication Specifications
a) Number of connectable power supplies: 1:N (N ≤ 32 power supplies)
b) Communication rate: 19,200, 9,600, and 4,800 bps are available for selection.
c) Control protocol: Asynchronous
d) Communication mode: Half-duplex
e) Character mode: ASCII II
f) Stop bit length: 1 bit
g) End: CR
h) Check digit: Even parity